#!/usr/bin/env """ make line datacubes and integrated maps and compare applying continuum selfcal NOTE: this is intended to be an interactive, iterative process so this is more a log that should be run by cutting and pasting into casa rather than as an executable script search "CHANGEME" for variables to be changed 10/9/15 MCA """ # ================================== Setup ===================================== # IV_142 M2.0 II # 15:59:25.25 -42:35:07.1 field = 40 # CHANGEME fitspw = '2,3,4,7,8,9' # line-free channels for fitting continuum linespw = '0,1,3,5,6,8' # line spectral windows (C18O, 13CO, CN) robust = 0.5 # CHANGEME imsize = [640,640] cell = '0.03arcsec' imagermode = 'csclean' outframe = 'lsrk' veltype = 'radio' width = '1.0km/s' start = '-3km/s' nchan = 16 xc = 316 # CHANGEME yc = 320 # CHANGEME in_a = 80 out_a = 120 aper = 0.5 boxwidth = 300. box = rg.box([xc-boxwidth,yc-boxwidth],[xc+boxwidth,yc+boxwidth]) # ================ Create continuum subtracted line datasets =================== uvcontsub(vis = 'f'+str(field)+'.vis', # full vis file for this field spw = linespw, # line spw (for cont subtraction) fitspw = fitspw, # cont spw combine = 'spw', solint = 'int', fitorder = 1, want_cont = False) # should not be changed. # ============================== 13CO line ===================================== # first try on 13CO line as thats going to be the brightest # os.system('rm -rf f'+str(field)+'_13co32*') clean(vis = 'f'+str(field)+'.vis.contsub', imagename = 'f'+str(field)+'_13co32', mode = 'velocity', start = start, width = width, nchan = nchan, outframe = outframe, veltype = veltype, restfreq = '330.58797GHz', niter = 100, threshold = 0, interactive = False, imsize = imsize, cell = cell, weighting ='briggs', robust = robust, imagermode = imagermode) # can't see gas or continuum emission # cleaned in automated mode without mask # export cube to fits file fbase = 'f'+str(field)+'_13co32' os.system('rm -rf '+fbase+'.cube.fits') exportfits(imagename=fbase+'.image',fitsimage=fbase+'.cube.fits') # redo moment0 maps (now excluding noisy first channel!!) # os.system('rm -rf f'+str(field)+'_13co32.mom0*') immoments(imagename = 'f'+str(field)+'_13co32.image', # CHANGEME (based on above analysis!!) outfile = 'f'+str(field)+'_13co32.mom0', moments = [0], includepix = [-10.0,100.0], chans = ('range=[2km/s,6km/s]')) # CHANGEME (based on above analysis!!) # export to fits file fbase = 'f'+str(field)+'_13co32.mom0' os.system('rm -rf '+fbase+'.fits') exportfits(imagename=fbase,fitsimage=fbase+'.fits') # measure flux im_max = imstat(imagename = 'f'+str(field)+'_13co32.mom0')['max'][0] im_rms = imstat(imagename = 'f'+str(field)+'_13co32.mom0', region='annulus[['+str(xc)+'pix,'+str(yc)+'pix],['+str(in_a)+'pix,'+str(out_a)+'pix]]')['rms'][0] im_flux = imstat(imagename = 'f'+str(field)+'_13co32.mom0', region='circle[['+str(xc)+'pix,'+str(yc)+'pix],'+str(aper)+'arcsec]')['flux'][0] print 'Flux = {0:.2f} mJy, rms = {1:.2f} mJy, S/N = {2:.1f}'.format(1000*im_flux, 1000*im_rms, im_flux/im_rms) # Flux = -82.20 mJy, rms = 31.05 mJy, S/N = -2.6 # view gas (continuum not detected) imview(raster=[{'file':'f'+str(field)+'_13co32.mom0'}]) # re-center image on source and use measure.py to get COG flux # os.system('rm -rf f'+str(field)+'_13co32.mom0_cropped*') ia.fromimage(outfile = 'f'+str(field)+'_13co32.mom0_cropped.image', infile = 'f'+str(field)+'_13co32.mom0.fits', region = box ) ia.close() exportfits(imagename = 'f'+str(field)+'_13co32.mom0_cropped.image', fitsimage = 'f'+str(field)+'_13co32.mom0_cropped.fits') ''' Measuring COG for M/f40_13co32.mom0_cropped.fits Assuming object center (300.0,300.0) Background: -1.32 mJy/beam km/s RMS in annulus 4.0-6.0 arcsec = 31.42 mJy/beam km/s i radius flux err snr (asec) (mJy) (mJy) 0 0.10 -10.03 7.28 -1.4 1 0.20 -31.28 22.59 -1.4 2 0.30 -54.14 33.42 -1.6 <-- ND 3 0.40 -72.17 45.02 -1.6 4 0.50 -82.20 51.75 -1.6 5 0.60 -68.36 58.34 -1.2 6 0.70 -31.08 65.95 -0.5 7 0.80 18.09 80.82 0.2 F = 18.09 mJy E = 80.82 mJy S = 0.22 D = 1.60 arcsec ''' # ======================== C18O line ========================================== # don't bother with selfcal as it doesn't help... # os.system('rm -rf f'+str(field)+'_c18o32*') clean(vis = 'f'+str(field)+'.vis.contsub', imagename = 'f'+str(field)+'_c18o32', mode = 'velocity', start = start, width = width, nchan = nchan, outframe = outframe, veltype = veltype, restfreq = '329.33055GHz', niter = 100, threshold = 0, interactive = False, imsize = imsize, cell = cell, weighting ='briggs', robust = robust, imagermode = imagermode) # can't see gas or continuum emission # cleaned in automated mode without mask # redo moment0 maps (now excluding noisy first channel!!) # os.system('rm -rf f'+str(field)+'_c18o32.mom0*') immoments(imagename = 'f'+str(field)+'_c18o32.image', # CHANGEME (based on above analysis!!) outfile = 'f'+str(field)+'_c18o32.mom0', moments = [0], includepix = [-10.0,100.0], chans = ('range=[2km/s,6km/s]')) # export to fits file fbase = 'f'+str(field)+'_c18o32.mom0' os.system('rm -rf '+fbase+'.fits') exportfits(imagename=fbase,fitsimage=fbase+'.fits') # measure flux im_rms = imstat(imagename = 'f'+str(field)+'_c18o32.mom0', region='annulus[['+str(xc)+'pix,'+str(yc)+'pix],['+str(in_a)+'pix,'+str(out_a)+'pix]]')['rms'][0] im_flux = imstat(imagename = 'f'+str(field)+'_c18o32.mom0', region='circle[['+str(xc)+'pix,'+str(yc)+'pix],'+str(aper)+'arcsec]')['flux'][0] print 'Flux = {0:.2f} mJy, rms = {1:.2f} mJy, S/N = {2:.1f}'.format(1000*im_flux, 1000*im_rms, im_flux/im_rms) # Flux = -31.25 mJy, rms = 35.74 mJy, S/N = -0.9 # view gas (continuum not detected) imview(raster=[{'file':'f'+str(field)+'_c18o32.mom0'}]) # re-center image on source and use measure.py to get COG flux # os.system('rm -rf f'+str(field)+'_c18o32.mom0_cropped*') ia.fromimage(outfile = 'f'+str(field)+'_c18o32.mom0_cropped.image', infile = 'f'+str(field)+'_c18o32.mom0.fits', region = box ) ia.close() exportfits(imagename = 'f'+str(field)+'_c18o32.mom0_cropped.image', fitsimage = 'f'+str(field)+'_c18o32.mom0_cropped.fits') ''' Measuring COG for M/f40_c18o32.mom0_cropped.fits Assuming object center (300.0,300.0) Background: 0.20 mJy/beam km/s RMS in annulus 4.0-6.0 arcsec = 35.20 mJy/beam km/s i radius flux err snr (asec) (mJy) (mJy) 0 0.10 0.91 9.93 0.1 1 0.20 4.77 24.90 0.2 2 0.30 17.22 34.00 0.5 <-- ND 3 0.40 13.74 43.22 0.3 4 0.50 -31.25 63.04 -0.5 5 0.60 -73.41 88.31 -0.8 6 0.70 -85.45 88.22 -1.0 7 0.80 -80.34 87.55 -0.9 F = 17.22 mJy E = 34.00 mJy S = 0.51 D = 0.60 arcsec ''' # ======================== Image CN ================== # don't bother with selfcal as it doesn't help... # os.system('rm -rf f'+str(field)+'_cn32_b4sc*') clean(vis = 'f'+str(field)+'.vis.contsub', imagename = 'f'+str(field)+'_cn32_b4sc', mode = 'velocity', start = start, width = width, nchan = nchan, outframe = outframe, veltype = veltype, restfreq = '340.24777GHz', niter = 100, threshold = 0, interactive = False, imsize = imsize, cell = cell, weighting ='briggs', robust = robust, imagermode = imagermode) # can't see gas or continuum emission # cleaned in automated mode without mask # redo moment0 maps (now excluding noisy first channel!!) # os.system('rm -rf f'+str(field)+'_cn32.mom0*') immoments(imagename = 'f'+str(field)+'_cn32_b4sc.image', # CHANGEME (based on above analysis!!) outfile = 'f'+str(field)+'_cn32.mom0', moments = [0], includepix = [-10.0,100.0], chans = ('range=[1km/s,7km/s]')) # CHANGEME (based on above analysis!!) # export to fits file fbase = 'f'+str(field)+'_cn32.mom0' os.system('rm -rf '+fbase+'.fits') exportfits(imagename=fbase,fitsimage=fbase+'.fits') # measure flux im_rms = imstat(imagename = 'f'+str(field)+'_cn32.mom0', region='annulus[['+str(xc)+'pix,'+str(yc)+'pix],['+str(in_a)+'pix,'+str(out_a)+'pix]]')['rms'][0] im_flux = imstat(imagename = 'f'+str(field)+'_cn32.mom0', region='circle[['+str(xc)+'pix,'+str(yc)+'pix],'+str(aper)+'arcsec]')['flux'][0] print 'Flux = {0:.2f} mJy, rms = {1:.2f} mJy, S/N = {2:.1f}'.format(1000*im_flux, 1000*im_rms, im_flux/im_rms) # Flux = 58.21 mJy, rms = 30.53 mJy, S/N = 1.9 # view gas (continuum not detected) imview(raster=[{'file':'f'+str(field)+'_cn32.mom0'}]) # re-center image on source and use measure.py to get COG flux # os.system('rm -rf f'+str(field)+'_cn32.mom0_cropped*') ia.fromimage(outfile = 'f'+str(field)+'_cn32.mom0_cropped.image', infile = 'f'+str(field)+'_cn32.mom0.fits', region = box ) ia.close() exportfits(imagename = 'f'+str(field)+'_cn32.mom0_cropped.image', fitsimage = 'f'+str(field)+'_cn32.mom0_cropped.fits') # CAN'T SEE GAS SO JUST USING 1" APER # 5 0.500 877 60.57 62.577 1.0 68.71 29.819 2.3 0.998