#!/usr/bin/env """ make line datacubes and integrated maps and compare applying continuum selfcal NOTE: this is intended to be an interactive, iterative process so this is more a log that should be run by cutting and pasting into casa rather than as an executable script search "CHANGEME" for variables to be changed 10/9/15 MCA """ # ================================== Setup ===================================== # III_1010 M2.0 II # 16:10:51.31 -38:53:12.8 field = 21 # CHANGEME fitspw = '2,3,4,7,8,9' # line-free channels for fitting continuum linespw = '0,1,3,5,6,8' # line spectral windows (C18O, 13CO, CN) robust = 0.5 # CHANGEME imsize = [640,640] cell = '0.03arcsec' imagermode = 'csclean' outframe = 'lsrk' veltype = 'radio' width = '1.0km/s' start = '-3km/s' nchan = 16 xc = 320 # CHANGEME yc = 320 # CHANGEME in_a = 80 out_a = 120 aper = 0.5 boxwidth = 300. box = rg.box([xc-boxwidth,yc-boxwidth],[xc+boxwidth,yc+boxwidth]) # ================ Create continuum subtracted line datasets =================== uvcontsub(vis = 'f'+str(field)+'.vis', # full vis file for this field spw = linespw, # line spw (for cont subtraction) fitspw = fitspw, # cont spw combine = 'spw', solint = 'int', fitorder = 1, want_cont = False) # should not be changed. # ============================== 13CO line ===================================== # first try on 13CO line as thats going to be the brightest # os.system('rm -rf f'+str(field)+'_13co32*') clean(vis = 'f'+str(field)+'.vis.contsub', imagename = 'f'+str(field)+'_13co32', mode = 'velocity', start = start, width = width, nchan = nchan, outframe = outframe, veltype = veltype, restfreq = '330.58797GHz', niter = 100, threshold = 0, interactive = False, imsize = imsize, cell = cell, weighting ='briggs', robust = robust, imagermode = imagermode) # can't see gas or continuum emission # cleaned in automated mode without mask # export cube to fits file fbase = 'f'+str(field)+'_13co32' os.system('rm -rf '+fbase+'.cube.fits') exportfits(imagename=fbase+'.image',fitsimage=fbase+'.cube.fits') # redo moment0 maps (now excluding noisy first channel!!) # os.system('rm -rf f'+str(field)+'_13co32.mom0*') immoments(imagename = 'f'+str(field)+'_13co32.image', # CHANGEME (based on above analysis!!) outfile = 'f'+str(field)+'_13co32.mom0', moments = [0], includepix = [-10.0,100.0], chans = ('range=[2km/s,6km/s]')) # CHANGEME (based on above analysis!!) # export to fits file fbase = 'f'+str(field)+'_13co32.mom0' os.system('rm -rf '+fbase+'.fits') exportfits(imagename=fbase,fitsimage=fbase+'.fits') # measure flux im_max = imstat(imagename = 'f'+str(field)+'_13co32.mom0')['max'][0] im_rms = imstat(imagename = 'f'+str(field)+'_13co32.mom0', region='annulus[['+str(xc)+'pix,'+str(yc)+'pix],['+str(in_a)+'pix,'+str(out_a)+'pix]]')['rms'][0] im_flux = imstat(imagename = 'f'+str(field)+'_13co32.mom0', region='circle[['+str(xc)+'pix,'+str(yc)+'pix],'+str(aper)+'arcsec]')['flux'][0] print 'Flux = {0:.2f} mJy, rms = {1:.2f} mJy, S/N = {2:.1f}'.format(1000*im_flux, 1000*im_rms, im_flux/im_rms) # Flux = -5.85 mJy, rms = 34.33 mJy, S/N = -0.2 # view gas (continuum not detected) imview(raster=[{'file':'f'+str(field)+'_13co32.mom0'}]) # re-center image on source and use measure.py to get COG flux # os.system('rm -rf f'+str(field)+'_13co32.mom0_cropped*') ia.fromimage(outfile = 'f'+str(field)+'_13co32.mom0_cropped.image', infile = 'f'+str(field)+'_13co32.mom0.fits', region = box ) ia.close() exportfits(imagename = 'f'+str(field)+'_13co32.mom0_cropped.image', fitsimage = 'f'+str(field)+'_13co32.mom0_cropped.fits') ''' Measuring COG for M/f21_13co32.mom0_cropped.fits Assuming object center (300.0,300.0) Background: 0.22 mJy/beam km/s RMS in annulus 4.0-6.0 arcsec = 31.08 mJy/beam km/s i radius flux err snr (asec) (mJy) (mJy) 0 0.10 6.27 9.09 0.7 1 0.20 13.00 26.13 0.5 2 0.30 13.13 33.47 0.4 <-- ND 3 0.40 9.31 51.40 0.2 4 0.50 -5.85 56.83 -0.1 5 0.60 -39.21 52.58 -0.7 6 0.70 -53.51 99.29 -0.5 7 0.80 -36.90 94.51 -0.4 8 0.90 -9.70 98.41 -0.1 9 1.00 26.43 103.30 0.3 F = 26.43 mJy E = 103.30 mJy S = 0.26 D = 2.00 arcsec ''' # ======================== C18O line ========================================== # don't bother with selfcal as it doesn't help... # os.system('rm -rf f'+str(field)+'_c18o32*') clean(vis = 'f'+str(field)+'.vis.contsub', imagename = 'f'+str(field)+'_c18o32', mode = 'velocity', start = start, width = width, nchan = nchan, outframe = outframe, veltype = veltype, restfreq = '329.33055GHz', niter = 100, threshold = 0, interactive = False, imsize = imsize, cell = cell, weighting ='briggs', robust = robust, imagermode = imagermode) # can't see gas or continuum emission # cleaned in automated mode without mask # export cube to fits file fbase = 'f'+str(field)+'_c18o32' os.system('rm -rf '+fbase+'.cube.fits') exportfits(imagename=fbase+'.image',fitsimage=fbase+'.cube.fits') # redo moment0 maps (now excluding noisy first channel!!) # os.system('rm -rf f'+str(field)+'_c18o32.mom0*') immoments(imagename = 'f'+str(field)+'_c18o32.image', # CHANGEME (based on above analysis!!) outfile = 'f'+str(field)+'_c18o32.mom0', moments = [0], includepix = [-10.0,100.0], chans = ('range=[2km/s,6km/s]')) # export to fits file fbase = 'f'+str(field)+'_c18o32.mom0' os.system('rm -rf '+fbase+'.fits') exportfits(imagename=fbase,fitsimage=fbase+'.fits') # measure flux im_rms = imstat(imagename = 'f'+str(field)+'_c18o32.mom0', region='annulus[['+str(xc)+'pix,'+str(yc)+'pix],['+str(in_a)+'pix,'+str(out_a)+'pix]]')['rms'][0] im_flux = imstat(imagename = 'f'+str(field)+'_c18o32.mom0', region='circle[['+str(xc)+'pix,'+str(yc)+'pix],'+str(aper)+'arcsec]')['flux'][0] print 'Flux = {0:.2f} mJy, rms = {1:.2f} mJy, S/N = {2:.1f}'.format(1000*im_flux, 1000*im_rms, im_flux/im_rms) # Flux = 23.39 mJy, rms = 34.76 mJy, S/N = 0.7 # view gas (continuum not detected) imview(raster=[{'file':'f'+str(field)+'_c18o32.mom0'}]) # re-center image on source and use measure.py to get COG flux # os.system('rm -rf f'+str(field)+'_c18o32.mom0_cropped*') ia.fromimage(outfile = 'f'+str(field)+'_c18o32.mom0_cropped.image', infile = 'f'+str(field)+'_c18o32.mom0.fits', region = box ) ia.close() exportfits(imagename = 'f'+str(field)+'_c18o32.mom0_cropped.image', fitsimage = 'f'+str(field)+'_c18o32.mom0_cropped.fits') ''' Measuring COG for M/f21_c18o32.mom0_cropped.fits Assuming object center (300.0,300.0) Background: 0.19 mJy/beam km/s RMS in annulus 4.0-6.0 arcsec = 35.96 mJy/beam km/s i radius flux err snr (asec) (mJy) (mJy) 0 0.10 -6.48 10.23 -0.6 1 0.20 -27.05 24.88 -1.1 2 0.30 -40.89 41.24 -1.0 <-- ND 3 0.40 -21.41 46.11 -0.5 4 0.50 23.39 55.97 0.4 5 0.60 57.33 67.78 0.8 6 0.70 40.89 96.37 0.4 7 0.80 -12.40 112.48 -0.1 8 0.90 -27.53 128.05 -0.2 9 1.00 17.98 118.36 0.2 F = 57.33 mJy E = 67.78 mJy S = 0.85 D = 1.20 arcsec ''' # ======================== Image CN ================== # don't bother with selfcal as it doesn't help... # os.system('rm -rf f'+str(field)+'_cn32_b4sc*') clean(vis = 'f'+str(field)+'.vis.contsub', imagename = 'f'+str(field)+'_cn32_b4sc', mode = 'velocity', start = start, width = width, nchan = nchan, outframe = outframe, veltype = veltype, restfreq = '340.24777GHz', niter = 100, threshold = 0, interactive = False, imsize = imsize, cell = cell, weighting ='briggs', robust = robust, imagermode = imagermode) # can't see gas or continuum emission # cleaned in automated mode without mask # redo moment0 maps (now excluding noisy first channel!!) # os.system('rm -rf f'+str(field)+'_cn32.mom0*') immoments(imagename = 'f'+str(field)+'_cn32_b4sc.image', # CHANGEME (based on above analysis!!) outfile = 'f'+str(field)+'_cn32.mom0', moments = [0], includepix = [-10.0,100.0], chans = ('range=[1km/s,7km/s]')) # CHANGEME (based on above analysis!!) # export to fits file fbase = 'f'+str(field)+'_cn32.mom0' os.system('rm -rf '+fbase+'.fits') exportfits(imagename=fbase,fitsimage=fbase+'.fits') # measure flux im_rms = imstat(imagename = 'f'+str(field)+'_cn32.mom0', region='annulus[['+str(xc)+'pix,'+str(yc)+'pix],['+str(in_a)+'pix,'+str(out_a)+'pix]]')['rms'][0] im_flux = imstat(imagename = 'f'+str(field)+'_cn32.mom0', region='circle[['+str(xc)+'pix,'+str(yc)+'pix],'+str(aper)+'arcsec]')['flux'][0] print 'Flux = {0:.2f} mJy, rms = {1:.2f} mJy, S/N = {2:.1f}'.format(1000*im_flux, 1000*im_rms, im_flux/im_rms) # Flux = 36.00 mJy, rms = 30.21 mJy, S/N = 1.2 # view gas (continuum not detected) imview(raster=[{'file':'f'+str(field)+'_cn32.mom0'}]) # re-center image on source and use measure.py to get COG flux # os.system('rm -rf f'+str(field)+'_cn32.mom0_cropped*') ia.fromimage(outfile = 'f'+str(field)+'_cn32.mom0_cropped.image', infile = 'f'+str(field)+'_cn32.mom0.fits', region = box ) ia.close() exportfits(imagename = 'f'+str(field)+'_cn32.mom0_cropped.image', fitsimage = 'f'+str(field)+'_cn32.mom0_cropped.fits') # CAN'T SEE GAS SO JUST USING 1" APER # 5 0.500 877 37.31 69.804 0.5 68.06 29.114 2.3 0.999